Readers ask: How To Properly Care For Dental Kavo Handpieces?

Readers ask: How To Properly Care For Dental Kavo Handpieces?

How do I take care of my dental handpieces?

Remember to wipe your handpiece down with warm water, or warm water with a mild detergent, prior to lubrication and sterilization. Using strong chemicals to do this is usually unnecessary, and may even cause problems with chemical interactions during sterilization.

How often should you lubricate dental handpieces?

Lubricate & Clean Internally Using a good quality service oil & the correct adaptor, insert into handpiece and spray for approx 2 seconds until oil comes from the head. You cannot over oil your handpieces. The spindle/chuck of handpieces should be lubricated once a day with the pointed lubricant adaptor.

How do you sterilize dental handpieces?

The acceptable methods of sterilization include chemical vapor sterilizers, dry heat, and autoclaves. Ethylene oxide gas is not recommended for dental handpieces.

How long do dental handpieces last?

The handpiece automatically senses the need for more power and increases torque. When their turbines are properly maintained, handpieces can last between 15 and 27 months, or several months past their warranty period.

You might be interested:  FAQ: How Much Is Dental Preventative Care Without Insurance?

How should dental handpieces be cared for weekly?

Clean the chuck weekly to maintain proper working condition. Use a small interproximal brush (or similar brush) dipped in alcohol. Insert the brush into the bur tube and rotate the brush several times. Repeat this process until the brush comes out clean.

Why do handpieces require lubrication?

Oil is the lifeblood of your dental handpieces, helping them to work smoothly and efficiently day in, day out. The reason for this is that oil helps to reduce the accumulation of varnish and carbon from collecting on the engine, not to mention that it is essential to pulling the heat away from the combustion chamber.

How many RPM can the high speed handpiece reach?

Reaching speeds as high as 420,000 rpm, high – speed air-turbine dental handpieces may outrun electrics, which generally top out at 200,000 rpm, but they lack the torque of the latter, and have been known to stall under load. In fact, their speed may drop as much as 40% or more once their burs hit a surface.

Can dental burs be sterilized?

Conclusions: Dental burs and endodontic files, as packaged by the manufacturer, are not sterile and should therefore be sterilized before first use.

How do you lubricate a slow speed handpiece?

Oil, in either a bottle or in a spray format, can be used.

  1. The low – speed handpiece can be broken down into three parts.
  2. Re-assemble and operate the handpiece for 10 seconds, then wipe clean the excess oil on the exterior of the handpiece. After these steps, it is ready to use.
You might be interested:  Quick Answer: What To Do To Get Dental Care If You Cant Afford It?

When lubricating a high speed handpiece lubricant should be placed in?

To lubricate the high speed handpiece, inject lubricant into the smallest of the two large holes until it’s lightly pours out. Before reusing it, attach it to your dental unit and run it for approximately 10 seconds.

Which of the following is acceptable for cleaning dental suction lines?

Suction lines in the hygiene treatment rooms should be cleaned every day with an evacuation system cleaner to remove blood and debris, and a disinfectant that is compatible with the evacuation system should be run through the tubing. The low-volume suction lines should be disinfected between patients.

What controls the dental handpiece?

Dental handpieces are medical devices regulated by the US Food and Drug Administration (FDA). Some handpieces are independent of air and waterlines (e.g., cordless devices). For these devices, CDC recommends that DHCP follow current FDA regulations.

How long do you sterilize dental instruments?

Sterilization times range from four to 30 minutes depending on temperature, whether instruments are wrapped or unwrapped, and manufacturer’s instructions. The drying cycle may be 25 to 40 minutes. Dry heat sterilizers are either static air or forced air.